The default tendon for post-tensioned bridges and heavy precast work. 140 mm² of steel, 260 kN minimum breaking load, supplied in 3–3.5 t coils with the mill's batch certificate.
| Property | Value |
|---|---|
| Construction | 1×7 seven-wire, left-hand lay (S) |
| Nominal diameter | 15.20 mm (ASTM 0.600 in) |
| Nominal steel area | 140 mm² |
| Grade | 1860 MPa (ASTM Grade 270), low relaxation |
| Minimum breaking load | 260.4 kN (= 140 mm² × 1860 MPa) |
| Measured breaking load, recent batches | Fm 267–273 kN |
| 0.2% proof load | Fp0.2 244–253 kN |
| Elongation at maximum load | 5.1–7.0% |
| Modulus of elasticity | 194–197 GPa |
| Relaxation | 1.1% at 70% Fm, 1000 h (standard allows 2.5%) |
| Coil weight | 3.0–3.5 t |
| Coil length | 2,700–3,300 m |
| Packing | Steel strap + wooden/steel support, waterproof paper or plastic-film wrap; light rust-preventive spray or non-oiled supply on request |
| Standards | GB/T 5224-2023; ASTM A416/A416M on request |
Measured values are taken from batch quality certificates for 1×7-15.20, 1860 MPa, 2026 production. They are typical, not a guaranteed minimum — the certificate for your own batch governs.
A 15.2 mm seven-wire strand has a nominal steel area of 140 mm². At 1860 MPa that gives a minimum breaking load of 260.4 kN — the figure your designer uses for tendon capacity. Recent batches measure 267–273 kN, about 3–5% above the minimum, which is normal for low-relaxation strand produced on modern lines.
Relaxation is the number that separates a cheap strand from a correct one. Standard low-relaxation strand is allowed 2.5% loss at 70% of breaking load over 1,000 hours; the batches we ship measure around 1.1%. Over a 30-year design life that difference is real, and it is why the mill's relaxation test report matters as much as the tensile test.
Supplied to GB/T 5224-2023 by default. For projects specified to US practice, the same product is produced and certified to ASTM A416/A416M Grade 270, low relaxation; 15.20 mm is the 0.600 in size. See the standard-by-standard comparison if you need to decide which to call for.
Coils are strapped with steel band, seated on wooden or steel supports, and wrapped in waterproof paper, hessian or plastic film. A light rust-preventive spray, or a non-oiled supply, can be agreed in the contract. Each coil is marked with size, grade, batch number, heat number, weight and length — the marking matches the certificate, so the coil can be checked on site without opening the wrap.
Full list: which documents come with the shipment.
Regular sizes: 5 working days from receipt of deposit. FOB Tianjin, CIF Karachi, or DDP into Pakistan through the Khunjerab route — details on the Pakistan delivery page. Minimum order is one 20 ft container, roughly 25 t.
Tell us tonnage and destination port — we reply within one business day.